This optional parameter allows you to define the way Radiator
interprets the result of the PCCRuleSelect
statement.
You can specify any number of
PCCRuleColumnDef
parameters, one for each interesting
field returned by PCCRuleSelect
. The general format
is:
PCCRuleColumnDef n, dataitem
n
is the index of the field in the result of
PCCRuleSelect
. 0 is the first field
dataitem
is the name of a entry in the
PCC rule information
The subscriber information entries required by the modules
shipped with Radiator policy and charging support use the following
information:
Table 2. PCC rule information fetched from the SPR
id |
Index or other identifier that uniquely identifies this
PCC rule set in the
SPR |
name |
Free form description of this rule set for humans. Not
used with Gx protocol |
rule_names |
Comma separated list of names of rules predefined in the
PCEF to activate |
rule_basenames |
Comma separated list of names of rule groups predefined
in the PCEF to activate |
dyn_rule_names |
Comma separated list of names in
dynamic_rules table |
activation_time |
Activation-Time for this
Charging-Rule-Install in Diameter Time
format |
deactivation_time |
Deactivation-Time for this
Charging-Rule-Install in Diameter Time
format |